Technical Specification:


Output

Output Power Capacity
315 Watts / 525 VA
Max Configurable Power
315 Watts / 525 VA
Nominal Output Voltage
230V
Topology
Standby
Output Connections
(1) Universal Receptacle (Surge Protection)
(3) Universal Receptacle (Battery Backup)

Input

Nominal Input Voltage
230V
Input Frequency
50 Hz +/- 3 Hz
Input Connections
IEC-320 C14
Cord Length
1.98 meters
Input voltage range for main operations
180 - 260V

Batteries & Runtime

Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time
10 hour(s)
Replacement Battery

Communications & Management

Interface Port(s)
DB-9 RS-232
Control panel
LED Status display with On Line : On Battery
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering

Surge energy rating
450 Joules
Data Line Protection
RJ-11 Modem/Fax protection (two wire single line)

Physical

Maximum Height
85.00 mm
Maximum Width
298.00 mm
Maximum Depth
183.00 mm
Net Weight
3.64 KG
Shipping Weight
4.20 KG
Shipping Height
118.00 mm
Shipping Width
335.00 mm
Shipping Depth
227.00 mm
Color
Charcoal
SCC Codes
1073130419161 9
Units per Pallet
120.00

Environmental

Operating Environment
0 - 40 °C
Operating Relative Humidity
0 - 95%
Operating Elevation
0-3000 meters
Storage Temperature
-5 - 45 °C
Storage Relative Humidity
0 - 95%
Storage Elevation
0-15000 meters
Audible noise at 1 meter from surface of unit
45.00 dBA
Online Thermal Dissipation
31.00 BTU/hr

Back-UPS Features & Benefits

Protection
Lightning and Surge Protection
Protection from surges, spikes and even lightning is guaranteed!
Resettable circuit breaker
Instead of a hard to find fuse, there is a push-button circuit breaker for easy recovery from an overload or short circuit.
Convenience
Audible alarms
Proactively notifies you of changing UPS and utility power conditions.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Transformer Block Spacing
Designed to allow the use of up to two transformer block plugs without blocking access to other receptacles.