Model: BR500CI-AS
Technical Specification:
Output
Output Power Capacity
300 Watts / 500 VA
Nominal Output Voltage
230V
Output Frequency (sync to mains)
47 - 63 Hz
Topology
Line Interactive
Waveform Type
Stepped approximation to a sinewave
Output Connections
(3) IEC 320 C13 (Battery Backup) |
Input
Nominal Input Voltage
230V
Input Frequency
50/60 Hz +/- 3 Hz (auto sensing)
Input Connections
IEC-320 C14 |
Cord Length
1.83 meters
Batteries & Runtime
Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time
10 hour(s)
RBC™ Quantity
1
Runtime Graph
Communications & Management
Audible Alarm
Alarm when on battery : distinctive low battery alarm
Surge Protection and Filtering
Surge energy rating
240 Joules
Physical
Maximum Height
185.00 mm
Maximum Width
115.00 mm
Maximum Depth
213.00 mm
Net Weight
4.90 KG
Shipping Weight
5.50 KG
Shipping Height
257.00 mm
Shipping Width
190.00 mm
Shipping Depth
291.00 mm
Color
Black
SCC Codes
0073130426979 3
Environmental
Operating Environment
0 - 40 °C
Operating Relative Humidity
0 - 95%
Operating Elevation
0-3000 meters
Storage Temperature
-15 - 45 °C
Storage Relative Humidity
0 - 95%
Storage Elevation
0-15000 meters
BR500CI-AS Features
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Status Indicator LED's
Provides a quick visual indication of your unit's status.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible alarms
Provides notification of changing utility power and UPS conditions
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Back-UPS Features & Benefits
Protection
Lightning and Surge Protection
Protection from surges, spikes and even lightning is guaranteed!
Resettable circuit breaker
Instead of a hard to find fuse, there is a push-button circuit breaker for easy recovery from an overload or short circuit.
Convenience
Audible alarms
Proactively notifies you of changing UPS and utility power conditions.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Transformer Block Spacing
Designed to allow the use of up to two transformer block plugs without blocking access to other receptacles.